AIR PERMEABILITY TESTER
Automatic Fabric Air Permeability Tester is used to test the air permeability of various woven fabrics, knitted fabrics, non-woven fabrics, industrial filter materials etc
Standards:
ASTM D737, ASTM D3574, AFNORG07-111, BS5636, DIN53,887,EDANA140.1, EN IS07,231, ENISO9,237, JIS L1096-A, TAPPI T251 and so on.
S Model: Manual replacement of the Orifice plate.
A Model: Automatic replacement of the Orifice plate.
- More excellent anti-jamming, more excellent stability, more rapid data transference speed.
- Adopt microcomputer control system, branded high accuracy pressure sensor, digital feedback and adjust air volume.
- Automatic orifice plate replacement, no manual replacement .
4.Automatic orifice plate replacement, no manual replacement
- Automatic follow, measure and display pressure difference of each point with high stability and repeatability.
- All plates have been calibrated by-point in full testing range to let test data more accuracy.
- All test data is displayed by large high-definition large color touch screen displayer, no need to calculate test result by hands.
- Automatic converse air permeability rate and air permeability volume to improve test efficiency.
- Large touch screen displayer and controller.
- Adopt micro-computer control, insure the test data accuracy and test data can be saved and processed automatically.
- Special designed sample holder accomplish test in box and ensure the yarn without slip.
- Equipped with the inner printer, test report can be printed anywhere.
- Testing procedure can be set conveniently by the inner control panel.
- 14 With the function of saving data when power-down.
- Professional software support to output results to PC.
Technical Parameters:
- Working pattern: high precision imported pressure sensor, touch screen control, printing and testing report
- Pressure volume : 50-500Pa
- Specimen thickness: ≤12mm
4 .Measuring accuracy : ≤±2%
- Test area/diameter: 20 cm2, 38 cm2 Optional : 50 cm2,100cm2, 5 cm2, φ50mm
- Units: Total 8 Units to can be freely switched: mm/s, L/m2/s, L/dm2/min, cm3/cm2/s, ft3/ft2/min, m3/m2/min, m3/m2/h, dm3/s
- Orifice plate: 8 Pcs ( Φ0.5mm, Φ1.0mm, Φ1.5mm, Φ2.5mm, Φ4.5mm, Φ8.0mm, Φ14.5mm, Φ26mm)
- Calibration : unique calibration board
- Permeability ratio range: 0.2-11000mm/s (L/m2.S)
- External Dimensions: 700x1000x1000mm
- Gross Weight: 100kg
- Power source: 220V±10% 50HZ
To alter the specification or modify the appearance without notice right is reserved
$5,525.00
Related Products
Random Tumble Pilling Tester. To determine the pilling and fuzzing characteristics of textile, fabrics. Stainless steel impellers rotate within individually lit aluminum chambers constantly tumbling test fabrics against cork liners for a pre-determined time controlled by a timer andaudible alarm. With 2 or 4 test chambers. Laboratory standard compressed air supply required.
XHF-03C-1 Randum Tumble Pilling Tester-2 test chambers
XHF-03C-2 Randum Tumble Pilling Tester-4 test chambers
Standards: ASTM D3512, DIN 53867, JIS L1076
Technical Parameter :
Rotating speed: 1200rpm
Size of Testing Cylinder: Diameter146mm, Depth:152mm
Sample Dimension: 105mmx105mm
Dimensions: 400x390x515mm (LxWxH), 420x55x570mm(LxWxH)
Weight: 31kg, 65kg
Original Accessories: SDL Cork Liners 50Pcs/Pack
Cotton Silver 1 Yarn
Photographic standards card 5Pcs/Set
Jigger Dyeing Machine is suitable to test the dyeing of cotton and linen cloth, viscose, man-made fiber, etc., and suitable for dye material, such as direct dyes, acid dyes, basic dyes, insoluble azo dyes, and reactive dyes, etc. This apparatus can achieve bleaching and dyeing with low-liquor ratio, simulates as nearly as possible the mechanism of production jigs.
Jigger Dyeing Machine is specially designed to satisfy the requirements of testing dye formula before quantity production of dyeing and finishing enterprise. This apparatus simulates as nearly as possible the mechanism of production jigs’ requirements of speed, temperature, pre-tension, etc. of real production process. Compared with production machine, this Laboratory Jig Dyeing Machine’s size is smaller, consumes small quantity of dye, and with short testing process, so operator is easier to change dye formula, and finds suitable dye formula in a short time. Therefore this machine is well welcomed by many dyeing and finishing enterprise
Manual Operation Mode Interface
Technical Parameter:
Control Mode: Touch Screen+ PLC
Effective Roller Width: ≤500mm
Roller Diameter: F 57mm- F 200mm
Cloth speed :0.5-8m/min +/- 0.001 m/min
Temperature Range and accuracy: Room Temperature -98℃+/- 2℃
Temperature Ratio: 1-3 ℃
Tension: 0-18kgs
Material tension control mode: the difference speed between A and B roller.
Cooling: automatic water cold system
Power: AC 380V, 50Hz
Application:
Digital Elmendorf Tear Tester, A computer controlled falling-pendulum instrument, to determine the ballistic tearing strength of textiles, plastics, paper or board.
It enables rapid determination of the dynamic resistance of materials designed to be subjected to strong shearing loads (e.g. fabrics) or liable to be damaged by sharp or heavy objects (e.g. paper bags). Subsequently, the test was naturally adopted for all materials in the form of sheet or films, cardboards, cloth, knitted fabrics, plastic films, aluminum foil, non-woven fabrics, complex flexible packaging etc. But does not apply to sparse fabric or stretch materials which tearing direction might be shift in test.
Procedure: The test is carried out on a specimen composed of one or more sheets of standard dimensions 100 x 63 mm, a crack in length of 20 mm of specimen is notched automatically, a usually with a distance of 43mm (1.7 in) remaining to be torn after initiating the tear. The energy of a pendulum of suitable weight is used to completely tear the specimen. The difference in the angle from the vertical of the center of gravity of the pendulum between the downswing and upswing is a measure of the energy absorbed in tearing the sample
This angular movement is measured with a digital encoder and is immediately converted to the mean tearing force for a single sheet by the microprocessor and software incorporated in the apparatus.
Standard: BS 4253, ASTM D1424/5734 , DIN 53862, BS EN ISO 13937, ISO1974/9290.
Features:
Works in accordance with all known test standards. RS-232 data output, equipped Tearing Test software Auto specimen notching
Repeatable, pneumatic specimen gripping system guarantees sufficient clamping pressure to avoid all slipping phenomena,
thus ensuring perfect reproducibility of the experimental conditions.
Automatic compensation for friction and leveling errors, no slave pointer, therefore no friction, alignment and maintenance problems.
Unit: N, gf, cN, Cp can be selected.
Specifications:
- Testing range: A hammer: 0~16N B hammer: 0~32N C hammer: 0~64N D hammer: 0~128N
- Testing accuracy:≤±0.2%F·S
- Tearing length:43mm
- Length of automatic cut:20±0.1mm
- Sample size:100×63mm
- Type of sample clamping: pneumatic clamping
- Power source:AC220V50Hz
- External dimension:520×380×700mm
- Weight: 68kg
Packing list of
No. | Name | Qty | Remark |
1 | Tearing Tester | 1 Set | |
2 | Cutting Templates | 1 Pc | For preparing Specimen |
3 | Cutting Knifes | 1 Pc | For preparing Specimen |
4 | Weights | 1 Set | |
5 | Software | 1 | |
6 | Air Compressor | 1 | Optional |
The perspiration tester is to determine color fastness to water, perspiration fastness in textiles
Standards:
Perspiration : AATCC 15 , EN ISO 1 05 E04 , DIN 54020 , JIS L0848 , BS 1006 E04 Water : AATC C 107, EN ISO 105 E01 , DIN 54006 , DIN54005 , JIS L 0846 , BS 10 06 E01
Sea water : AATCC 106 , EN ISO 105 E02 , DIN 54007 , JIS L0847 , BS 1006 E02 Application :
It is to deter mine color fastness test t o water, sea water, perspiration fastness in textiles and sublimation during storage. Perspiration tester consists of a stainless steel frame with 21 acrylic separator plates to hold 20 samples. An electric precise oven is required.
Test Procedure:
Treat the composite sample with synthetic perspiration, sea water or water. Place the perspiration tester with 20 samples which held between plates under a given pressure by standard loading weight into an oven for a requested time at a requested temperature.
Compare the degree of fading and pollution of attached white cloth with gray scale, and appraise the perspiration color fastness
Technical Parameter:
AATCC Count Weight: 3.63kg (8LB)
ISO Count Weight: 4.08 kg (9LB)
Laminate w eight: 0.90kg (2LB)
AATCC acrylic separator plates: (22 Pcs)
ISO acrylic separator plates: (21 Pcs)
Weight: 8 K g
Dimensions: 420mm*15 0mm*300 m m(LxWxH)
Fabric Thickness tester is applicable of measuring the thickness o f tissue pap er, woven, knitted fabric s, non- woven and o ther uniform materials. It is designed according to
Standards: ISO5084 ,FZ/T6000 4, ISO9073, ISO 98 63….etc.
Technical Para meter :
Thickness measuring range : 0-25mm
Min. graduation value : 0.001 mm
Press foot diameter: 11.28mm , 50.48 mm, 56.42 mm, 112.84 mm
Press er foot area : 100, 2000, 2500, 1000 0(mm2)
Weighing poise : 5cN*1, 10cN*2, 50cN*2, 100cN*1,4 00cN*1,1000 cN*1 (combine)
Press time: 10s,30s
Test speed: when press time is 10s, about 2.1 times/minutes; when press time is
30s, 1.2 times/minutes.
Weight : 30kg
External Dimensions : 210x450x400mm
Power source : A C220V±10% 50Hz
Ozone Test Chamber is used to determine the colorfastness of textiles
when it is exposed to ozone in the atmosphere at room temperature..
Features:
The instrument consists of a stainless steel experimental chamber and a fully enclosed gas circuit for the production of ozone by silent discharge. The entire ozone gas generated and captured is enclosed to ensure personal safety. Ozone aeration chamber: composed of ozone generator, fan, baffle, sample compartment.
Standard: AATCC 109, ISO 105 G03
Temperature control range | 0-80℃, control accuracy: +-0.2℃ |
Humidity control range | 30-98%,ontrol accuracy: +-2% |
Ozone concentration | 0-200p.p.h.m,control accuracy:+-1p.p.h.m |
Ozone chamber size | 500mm (W)x400mm(D)x400mm (H) |
Sample Hanger | 2 layers |
Weight | 90Kgs |
Ozone generation system | |
The system uses high-precision ceramic high-voltage plate discharge. | |
Ozone concentration range | random setting 0-500pphm |
Ozone removal device | Activated carbon |
Ozone detection system | |
Detection range | 0-200pphm |
Measurement accuracy | +-2%,display resolution:0.1pphm |
This machine is used to determine not only the fabric hydrostatic pressure resistance, but also the hydrostatic pressure proof performance of the coating materials.
Standards: ISO-811, AATCC 127, BS EN20811, ISO 1420
Features:
Microcomputer control, English LCD menu, four built-in test methods .
The built-in tank design, creative balance system of water pressure rate, rising speed stability and accuracy.
Clamp made of stainless steel, equip LED light to view specimen clearly
Testing Methods:
Turbocharged Constant pressure time
(It means at the constant pressure, how long can appear the first water drop on the specimen)
Constant pressure regularly (It means at the constant pressure and specify time,
if can appear water drop on the specimen).
Leakage water method
Technical Parameter:
Testing range: 0.5kpa-200kpa
Accuracy: 0.2%F.S
Elevation Speed: 1kpa-30kpa
Clamp Area: 100cm2
Testing Units:(pa mmHg cmH2O)
Power: AC 220V 50Hz
Dimension: 550x400x500mm
Weight: 55kg
First spectrophotometer in China
- Obtained China Metrology Accreditation Certificate Large data storage space Large TFT display screen
- Modern and fashionable design based on human engineering
- Easy to use operation modes and compact operation interface
- Pre-locating panel design for easy instrument calibration
- Uses LED light source; high capacity rechargeable lithium-ion battery
- Can measure both SCI (specular included) and SCE (specular excluded) at the same time
- Includes PC software to manage data
- Can connect to mini-printers for printing
High performance-price ratio among international similar products
As China’s first spectrophotometer, integrates multiple innovative technical characteristic, and extends the boundary of on-site color quality control during production;
It can be applied to laboratories, factories and on-site operations, and can achieve the best color management across all application fields’ quality control
Allows medium and small companies to obtain high performance color management system with relatively low price
The software contains all necessary color equations, standard light sources, and a large number of standards for specific industries and applications
Operation system supports both English and Chinese interfaces, and we offer to design the interface in other languages based on the need of our customers.
Professional design, powerful instrument functions
Professional horizontal design and it does not have any moving parts, which avoids the shaking of the instrument during measurement process.
This makes the measurement more accurate
PC software for easy measurement data management
Can measure both SCI and SCE at the same time
Large data storage space: can store up to 100 sets of standard samples, with up to 200 measurement records for each standard sample
Adding powder test accessories, easily measure the color of the Powder, granules and other samples
Manual Crock meter is used for testing the fastness to dry or wet rubbing
and the fastness to brushing of all kinds of colored textiles, digital display.
Standards: ISO105-X12, D02, Bs1006 D02, DIN54021, IWS Tm165, JIS K6328. AATCC8/165
Technical Parameter :
Testing times 1-99999
Rubbing travel 104±3mm
Rubbing speed Manual
Rubbing pressure 9N
Rubbing head Roundness :ф 16mm
External Dimensions 620*160* 230mm
Optional Accessories:
AATCC crocking clothes 1Box (1000Pcs)
ISO Grey Scale
AATCC Grey Scale.
This Tabletop spectrophotometer has the advantage of excellent inter-instrument agreement, high accuracy and good replicability.
It could meet your requirement for both color quality control and color matching very easily.
Brief Introduction
- Transmission D/0 Structure and Reflection D/8 Structure
- Double Optical Paths Spectral Analysis Technology.
It could get the measurement sample data and internal environment data at the same time to make sure the testing accuracy and
stability for long time running.
- Compatible with SCI/SCE Measurement.
Adopt D/8 illuminant condition recommended by the CIE to meet the color testing requirement for different industries. It could measure with SCI and SCE to see the color data change more clearly.
- Four Testing CalibersIt is easy to adjust the testing calibers.The largest caliber diameter reaches 25.4mm. It could test the sample with different sizes.
This is not only suitable for testing the color of opacity sample, but also suitable for transparent or translucent sample’s transmittance and turbidity.
- Large screen display and Stand-alone operation.It could finish the sample test without connecting with the computer. Large screen display to make sure customer could see the testing result directly and clearly and it will be more convenient to set the instrument status. The color quality management software and color match software are optional according to customer’s need.
- Unique Calibration Board Design.Fix the calibration board on the testing caliber to make sure the accuracy of the white calibration and guarantee the high accuracy for measurement.
- Flexible Test Fixture.It could fix the sample with different size and thickness on the testing port tightly in case of stray light entering to affect the testing accuracy.
Technical Data:
Type | XHF-CS-820 | |
Measurement Condition | Reflection: d/8(Diffused lighting, 8 degrees receiving) Compatible with SCI/SCE Measurement ISO7724/1、DIN5033 Teil7、JIS Z8722 condition C、CIE No.15、ASTM E1164)Transmission d/0(Diffused lighting, Vertical direction receiving) | |
Size of integrating sphere | Φ15.2cm, Alvan diffused reflection surface coating | |
Illumination Light source | CLEDs(entire wavelength balanced LED light source) | |
Sensor | dual light path sensor array | |
Wavelength range | 400-700nm | |
Wavelength interval | 10nm | |
Half spectral width | 5nm |
Reflectivity range | 0-200% | |
Reflectivity resolution | 0.01% | |
Observation angle | 2°/10° | |
Measurement light source | A,C,D50,D55,D65,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12
CWF,U30,DLF,NBF,TL83,TL84 |
|
Data being displayed | SPD distribution/data, sample’s color values, color difference Values / graph, pass/fail results, color error tendency, history data color
simulation, manual input standard sample, generate measurement report |
|
Measurement time interval | 2 seconds | |
Large Aperture (LAV):2.54cm (=1inch) | ||
Reflection Aperture | Medium Aperture (MAV):1.5cm(=0.6inch) | |
Small Aperture (SAV):0.75cmx1.0cm(0.3inch x 0.4inch) | ||
Very Small Aperture (VSAV):0.3cmx0.8cm(0.12inch x 0.31inch) | ||
Color space | CIE-L*a*b,L*C*h,CIE-L*u*v,XYZ,Yxy,Transmittance, Hunterlab, | |
Munsell MI,CMYK, RGB,HSB | ||
Color difference formulas | ΔE*ab,ΔE*CH,ΔE*uv,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*94,ΔE*00 | |
ΔEab(Hunter),555color classification | ||
Other colorimetric indices | WI(ASTM E313-10,ASTM E313-73,CIE/ISO, AATCC, Hunter, Taube
Berger, Ganz, Stensby),YI(ASTM D1925,ASTM E313-00,ASTM E313-73),Tint(ASTM E313-00,CIE,Ganz),Metamerism index Milm, Stick color fastness, Color fastness, APHA, Pt-Co, Gardner |
|
Repeatability | light splitting reflectivity: standard deviation within 0.08% color values: ΔE*ab<=0.015(After calibration, standard deviation of 30 measurements on test white board, 5 second intervals, Maximum: 0.03 | |
Interface | USB | |
Data storage | mass storage | |
Light source longevity | 5 years, 1.5 million tests | |
Size | 583*330*304mm(L*W*H) | |
Work temperature range | 15℃-32℃ (60°F-90°F) | |
Relative Humidity | 0℃ to 45℃,relative humidity 80% or below at 35°C, no condensation | |
Standard accessories | AC power line, color management software, drive software, USB
cable, black/white calibration tube, 40*10 cuvette, cuvette support, testing report |
|
Optional | 40×40 cuvette | |
Application:
It is used for color matching of any product under different lights, it is wide ly applied in Textile, toy, printing, plastic, rubber, chemical, ink, ceramic,
leather, , paints, chemicals, footwear, leather, metal, food, cosmetics multi-industry field.
Meets to m ajor international standards for visual color evaluation including:
ASTM D17 29, ISO3664, DIN, ANSI and BSI.
Tube length: 12 00mm
Easy to operate by using individual switches for each light source.
Elapsed time meter for tracking optimal l amp replacement.
Automatically alternating among light sources.
No warm-up time or flickering which insures quick and reliable color judgment
Economic power consumption and low heat generation for high light efficiency
Lights:
Model | Name | Pcs | Power | Color Temperature |
Six Lights
220V, 50Hz |
D65 | 2 | 36W/Piece | 6500K |
TL84 | 2 | 36W/Piece | 4000K | |
F/A | 6 | 40W/Piece | 2700K | |
UV | 1 | 40W/Piece | 365nnm | |
CWF | 2 | 36W/Piece | 4200K | |
U30 | 2 | 36W/Piece | 3000K |
To alter the specification or modify the appearance without notice right is reserved
Yarn count machine works with textile electronic balance is a kind of intellectual measuring instrument with weighing, counting and other many functions. The product introduces imported Integrated circuit and enjoys stable and reliable performance, easy operation and accurate weighing and counting. As a kind of measuring instrument, it has been widely used by enterprises and scientific research institutions.
Function:
It has: g,oz,tex,Nm,Ne,D,g/m2kinds of the units to change. Select 1-10 pcs specimen measurement
It can print the date, time, specimen length, each weighing value, calculated MIN (minimum), MAX (maximum), SUM (sum), AV (average), CV% (non-uniform rate). Overload malfunction indication.
Working Condition:
Working Temperature: 0°~40°C
Maximum Consumed Power: 3W
Pan Size: Diameter 80mm
Power Supply: Adaptor input -220V±10﹪, 50HZ±1HZ。Output- 9v,300mA
Comparative Humidity: 50﹪~85﹪
Range: 210g
Accuracy: 1mg (0.001g)
Standard Configuration: Balance, Printer, Calibration Weight